1.10 Use clean vials, caps, and plates a. Use Waters-brand vials; they have been certified as contaminant-free.4 Other vials may not be clean or may have caps containing adhesives that can contaminate the sample manager. b. Make sure the liner on your vial and bottle caps does not contain contaminants (check the manufacturer’s description):
Cryogenic dot labels are ideal for labeling 0.2ml PCR tube tops, 0.2ml PCR tube caps, 0.2ml PCR tubes, 0.2ml PCR vial caps. These labels can withstand high temperatures at +110°C and the labeled PCR vials can be placed inside PCR thermo cycler and PCR machines and undergo the complete PCR cycle.
HPLC bottles hold the mobile phase of high-performance liquid chromatography, often acting as a reservoir for the solvent. The bottles are made from borosilicate glass or highly durable plastics such as Teflon. Special caps prevent particulate matter from contaminating the mobile phase and possible spills.
Fisher Scientific - Lagoas Park, Edificio 11 - Piso 0 - Porto Salvo Tel. +351 21 425 33 50 - Fax. +351 21 425 33 51 - pt.fisher@thermofisher.com
GOOD LABORATORY PRACTICE for HPLC I- Preparation of solvents Correct solvent preparation is very important. It can save vast amounts of time spent troubleshooting spurious peaks, baseline noise, etc I-1. Quality All reagents and solvents should be of the highest quality. HPLC grade
Vials Thermo Scientific™ Nunctrade; Kryoröhrchen für Biobanking und Zellkulturen Speichern Sie Proben von der allgemeinen Kühllagerung bis zur Lagerung in der Gasphase über flüssigem Stickstoff mit Thermo Scientific™ Nunc™ Kryoröhrchen für Biobanken und Zellkulturen.
Aijiren 2ML 9-425 HPLC Vial is used for pre-sampling for chromatography solutions.It is applicable to kinds of autosamplers, such as autosamplers from Waters, Thermo Fisher, Shimadzu and so on.
CUSTOMER SPECIFIC STOCKING SAVING SPACE, TIME AND EXPENSE. TIMELY RESPONSES TO URGENT SITUATIONS. Product was successfully added to your shopping cart.
Antibodies & Protein Biology Antibody Production & Purification; Electrophoresis, Western Blotting and ELISA
4. Good Laboratory Practice for HPLC 30 4.1 Preparation of Solvents 30 4.1.1 Quality 30 4.1.2 Buffers 30 4.1.3 Filtration 30 4.1.4 Degassing 31 4.2 Solvent Use 31 4.2.1 Instrument 31 4.2.2 Mobile Phase Properties 32 4.3 Changing Solvents 32 4.3.1 Buffered Phase to Wash or Storage Phase 32 4.3.2 Normal to Reversed Phase and Vice Versa 32 4.3.3
It’s not unusual for an analytical chemistry lab to run between 250 and 1,000 autosampler vials a day. As a result, vial labeling becomes so difficult and time consuming that many analytical chemistry labs turn to unreliable hand-written vial labels for analytical chemistry or run autosampler vials without any label at all.
A complete range of consumables for HPLC, GC and Headspace analysis. This comprises vials, septa, seals, filters, crimpers, and other accessories. Besides all standard items for almost all common instruments in the chromatography market. La-pha-pack – Vial and Closure. Part of Thermo Fisher Scientific
Thermo Fisher Scientific, Germering, Germany Keywords UHPLC, HPLC, USP <621>, gradient delay volume, column thermostatting, extra-column volume, detector settings WHITE PAPER 72711 An instrument parameter guide for successful (U)HPLC method transfer
There’s a Thermo Scientific vial & closure for every HPLC, GC, MS instrument, application, and budget. Autosampler Vials & Caps for HPLC & GC | Thermo Fisher Scientific - US Popular
Thermo Scientific™ SureStop™ vials are designed as part of the Advance Vial Closure System (AVCS), and remove any subjectivity around achieving the optimal compression when sealing a vial. As an integral component of AVCS technology, SureStop™ vials offer the sealing and performance characteristics of a crimp top vial and the versatility