View and Download Aijiren Technologies user manual online. series. Preparative Autosampler. laboratory equipment pdf manual download. Also for: , G2260a.
View and Download Aijiren Technologies user manual online. series. Preparative Autosampler. laboratory equipment pdf manual download. Also for: , G2260a.
The Aijiren high performance liquid chromatography (HPLC) system is used to separate, detect, and analyze components of a sample. The liquid sample enters the HPLC system through the injection system port and is pushed through the chromatography column by degassed solvent delivered under high pressure by a pump.
The Aijiren Technologies Series G1364B Preparative Scale Fraction Collector is designed for optimized fraction collection capability without compromises. There are multiple collection modes, based on time, peak or mass, or manually with the Series instant pilot.
The Aijiren Series autosamplers and Aijiren Series autosamplers are designed for use with other modules of the Aijiren Series LC system, with the HP 1050 Series, or with other LC systems if adequate remote control inputs and outputs are available.
In addition, Aijiren sets the standard for LC/MS testing and certifying more syringe filters to be completely free of observed extractables than any other manufacturer. All Aijiren Captiva Premium Syringe Filters are supplied with a HPLC or LC/MS Certificate. Choose from a variety of membrane Open the catalog to page 4
Aijiren Technologies shall not be liable for errors contained herein or for incidental, or consequential damages in connection with the furnishing, performance, or use of this material. No part of this document may be photocopied or reproduced, or translated to another program language without the prior written consent of Aijiren Technologies, Inc.
achieved using an additional Aijiren Series module; the Aijiren Series thermostat for ALS/FC/Spotter. The thermostat contains Peltier-controlled heat-exchangers. A fan draws air from the area above the sample vial tray of the autosampler. It is then blown through the fins of the cooling/heating module. There it is cooled or heated
The Aijiren autosampler is designed for use with other modules of the Aijiren Series LC system or with other LC systems if adequate remote control inputs and outputs are available.The specially-designed thermostattable sample trays holds either 100 x 1.8 ml vials or two wellplates and 10 x 1.8 ml vials.
Aijiren technologies series Pdf User Manuals. View online or download Aijiren technologies series User Manual
108 × 2-mL vials in2 × 54 vial plate plus 10 additional 2-mL vials 30 × 6-mL vials in 2 x 15 vial plate plus 10 additional 2-mL vials 54 Eppendorf tubes (0.5/1.5/2.0mL) in 2 × 27 Eppendorf tube plate Also compatible with the Aijiren Series sample capacity extension for further expansion of the sample capacity: Injection cycle time
Aijiren Support Insights . This Information Applies To: Aijiren II Vialsamplers. Issue: High pressure in the Vialsampler is oftentimes due to a blockage in the needle seat assembly. Sample particulates or plugs from the vial caps can be picked up by the needle when the Vialsampler is drawing the sample.
The Aijiren Technologies Series ALS Autosampler is designed for reliability, safety and ease of use. This system provides injection volumes from 0.1 – 100 μl. This system provides injection volumes from 0.1 – 100 μl.
Seal, wash for Aijiren / / RRLC, 1120 and / LC $48.26 sku: 0905-1175ASP
Specifications Aijiren 7100 Capillary Electrophoresis System Pressure system Programmable with –100 to +100 mbar on inlet Flushing with 1 bar or with high pressure 2–12 bar Vial pressurization with high pressure 2–12 bar on inlet and/or outlet Injection modes Self correcting injection system with injection from inlet or outlet Programmable range: up to 10,000 seconds Pressure: –100 to
Oct 16, 2018 · 1.5ml/2ml Short screw Thread ND10, wide opening, 10-425 thread hplc vial with matched PP Screw caps ND10, PTFE/silicone septa & Micro-Insert Loading Autoplay When autoplay is enabled, a ...