News
Home » News » 2ml hplc lab vials » Ebay glass laboratory vials with label for hplc system
1.5ml 9mm Short Thread Autosampler Vials ND9
1.5ml 9mm Short Thread Autosampler Vials ND9
1.5ml 9mm Short Thread Autosampler Vials ND9
1.5ml 9mm Short Thread Autosampler Vials ND9
1.5ml 9mm Short Thread Autosampler Vials ND9
1.5ml 9mm Short Thread Autosampler Vials ND9
1.5ml 9mm Short Thread Autosampler Vials ND9
1.5ml 9mm Short Thread Autosampler Vials ND9

Ebay glass laboratory vials with label for hplc system

Material: USP Type 1, Class A, 33 Borosilicate Glass Volume: 2ml (standard volume) 1.5ml(actual volume) Application: HPLC and GC system Dimensions: 11.6 x 32mm Neck Diameter: 9mm Qty/Pack: 100pcs/pack Payment: T/T MOQ: 1pack
Contacting via phone: 0086-18057059123
Share us:
Description

DURAN® GLS 80 Protect wide mouth graduated laboratory bottles

Duran® GLS 80 Protect wide mouth graduated laboratory bottles volume 5,000 mL; Synonym: lab bottle, lab bottles, wide mouth glass; find null-Z674257 MSDS, related peer-reviewed papers, technical documents, similar products & more at Sigma-Aldrich.

Mobile Phase Accessories / HPLC Accessories / Supplies

Safety filter protects your lab from volatile compounds in waste bottles. 1/4-28 threads for use on Mobi-Cap or Hub-Cap bottle tops. Replace filter every 3 months or when indicator changes color; more frequently with rigorous use or use in harsh environments.

Automated Autosampler Vial Labels - Tubewriter 360

It’s not unusual for an analytical chemistry lab to run between 250 and 1,000 autosampler vials a day. As a result, vial labeling becomes so difficult and time consuming that many analytical chemistry labs turn to unreliable hand-written vial labels for analytical chemistry or run autosampler vials without any label at all.

Laboratory Procedure Manual

Jun 21, 2010 · 2. Replace regular autosampler vial with silanized autosampler vial. 3. Adjust sample preparation procedure by adding sample to the autosampler vial first before adding IS. 4. Prepare new standards and QC pools. 5. Update QC range. 6. Modify the procedures for regenerating HPLC columns. 7. Use 100 % H 2O for peak focusing instead of 80 % H 2O

Brady Label Makers & Printers | Fisher Scientific

Team-based research and inter-lab collaboration has emerged around the world. As your lab needs to continually demonstrate productivity improvements and cost reductions, bring in Brady as your partner for achieving and sustaining your lab performance goals with dependable and performance-tested identification, tracking and safety products.

Vials | Aijiren

Aijiren certified 2 mL screw top vials are constructed from from Type 1 borosilicate glass, with low metal content, to protect your sample from destabilizing or leaching. The associated 9 mm screw caps and closures are available with septa constructed from either PTFE silicone or natural red rubber.

Duran® graduated laboratory bottles, without caps capacity

Duran® graduated laboratory bottles, without caps capacity 250 mL, clear glass; find null-Z232084 MSDS, related peer-reviewed papers, technical documents, similar products & more at Sigma-Aldrich.

Vials, 2 mL crimp top, clear glass, 12 x 32 mm clear glass

Vials, 2 mL crimp top, clear glass, 12 x 32 mm clear glass vial, vial type, standard opening, pkg of 100 ea; find Supelco-27068-U MSDS, related peer-reviewed papers, technical documents, similar products & more at Sigma-Aldrich.

HPLC Products from Cole-Parmer

Whether you need HPLC for pharmaceutical, foods, environmental or other applications, we can meet your HPLC needs. We offer the latest HPLC products and systems. An HPLC system typically consists of a solvent delivery system, sample injection valve, high-pressure column, detector, and a computer to control the system and display the results.

Protocol -KitAlysis High-Throughput Palladium Precatalyst

Using a clean pipette each time, remove a 25 µL aliquot from each vial into corresponding HPLC vials or HPLC block . Be careful to pull material from the top of the vials to avoid any precipitate. Run on HPLC auto sampler. You may need to adjust the amount of acetonitrile from the suggested 700 µL to accommodate your unique HPLC system.

Controlling Contamination in UltraPerformance LC /MS and HPLC

IF YOUR SYSTEM CONTAINS FUSED SILICA AND GLASS COMPONENTS (FOR EXAMPLE, IF YOU HAVE A NANOACQUITY UPLC™ SYSTEM), AVOID USING SOLVENTS WITH A PH GREATER THAN 10. 1. Stuart Williams, “Ghost peaks in reversed-phase gradient HPLC: a review and update,” Journal of Chro-matorgraphy A, 2004, 1052, 1-11.

Test Tubes, Vials, Caps, and Closures | Fisher Scientific

Vials. Vials are available in a variety of styles. Find autosampler vials, vial caps and closures, and vial inserts for chromatography with snap, screw, or crimp-top closures, with and without septa. Autosampler vials come in convenient pre-packaged sets.

Antibodies & Protein Biology - Lab Equipment and Lab Supplies

DWK Life Sciences Wheaton™ Clear Glass Sample Vials in Lab File with Caps Attached Attached caps help maintain cleanliness. Wheaton™ Clear Glass Sample Vials in Lab File With Caps Attached come in partitioned trays to provide an easy way to store empty vials or to inventory samples.

Determination of N‐nitrosonornicotine (NNN) in Smokeless

Amber HPLC vials. 0.45 μm polytetrafluoroethylene (PTFE) or polyvinyldifluoride (PVDF) membrane syringe filters. Waters 2.1 x 50 mm, 2.5 µm Xterra MS C18 HPLC column (P/N: 186000594)

Tube Labeling | Vial Labeling | Lab Labels - TubeWriter 360

Use the TubeWriter™ 360 ink-delivery system to print directly onto any tube, vial, slide, cassette or microplate. Eliminate sticky lab labels that can fall off or jam delicate machines. With TubeWriter™ and ID Scribe you can label anything that fits under the inkjet print head at blazing fast speeds.

Submit Demands Online
Please feel free to submit your inquiry information to us. We will contact with you as soon as possible.
* Your email:
* Your name:
Company Name:
Tel:
* Message: