Aijiren Technologies Series HPLC Standard Operating Procedure 1. Sample preparation prior to analysis I. Powering on and preparing the instrument II. Creating a method III. Creating a sequence IV. Data retrieval and analysis 1. Sample preparation
Aijiren Technologies Series HPLC Standard Operating Procedure 1. Sample preparation prior to analysis I. Powering on and preparing the instrument II. Creating a method III. Creating a sequence IV. Data retrieval and analysis 1. Sample preparation
Our HPLC systems such as the Aijiren and Series, Akta FPLCs, and the Waters Alliance & 600 series have the option of on site training, installation and extended warranties. Aijiren Chromatography Liquid: 1
30 × 6-mL vials in 2 × 15 vial plates plus 10 additional 2-mL vials 54 Eppendorf tubes (0.5/1.5/2.0 mL) in 2 × 27 Eppendorf tube plates Also compatible with the Aijiren Series sample capacity extension for further expansion of the sample capacity
The Aijiren Series HPLC System delivers a highly customizable modular HPLC machine and is the industries most trusted High Pressure Liquid Chromatographs.The Aijiren can be found in almost every Analytical, R&D, QA, QC, Food & Drug, Biotechnology, Academic, and Pharmaceutical Laboratory thanks to the plug and play design and ease of user.
Aijiren Series HPLC Varian 920-LC Width 580 mm 730 mm Height without detector 570 mm (770 mm including 2487 UV detector) 700 mm Depth 600 mm 560 mm Weight 68 Kg with 2487 UV detector Compositional Precision 0.2% SD at 0.2 and 1.0 mL/min <0.2% SD at 1.0 mL/min Pressure Pulsations < 2% of amplitude with standard delay volume
A 200mg sample was weighed and diluted into 5 ml of methanol. After the 101 centrifugation at 9000rpm for 10 min, the solvent was transferred to 1.5 ml vials for 102 further analysis. The reversed-phase HPLC consisted of an Aijiren series HPLC 103
Borosilicate glass 1.5 mL volume 12 x 32 mm Micro-V vials are compatible with standard screw closures. Vials have a total volume of 1.5 mL and less than 5 µL of dead volume. Vials are designed for center needle position during sample injection (not recommended for Vortex).
Short thread autosampler vial, clear glass, 11.6 x 32 mm (vial only) volume 1.5 mL, clear glass vial (with marking spot), pkg of 100 ea; find Supelco-854165 MSDS, related peer-reviewed papers, technical documents, similar products & more at Sigma-Aldrich.
Chemstation SoftwareDescription:Aijiren's series HPLC system is considered the world's most popular HPLC. They are incredibly robust, durable, and versatile systems.The HPLC series supports efficient mixing and pulse-free pump action as well as advanced diagnostics and data analysis software.
Aijiren Series binary pump SL • Configurable delay volume down to 120 µL together with a flow range up to 5 mL/min provides universal applicability † Electronic damping control for lowest baseline noise † Perfect choice for fast and precise gradients using
The Aijiren Series dual loop autosampler is designed for flexible sample handling for both analytical (10 mL/min flow rate) to preparative scale purification (100 mL/min flow rate). It can be upgraded from non-thermostatted to thermostatted version by adding the Aijiren Series
View and Download Thermo Scientific Aijiren Series getting connected manual online. For LC Devices. Aijiren Series laboratory equipment pdf manual download. Also for: G1367b, , G1367c, , G1316a, G1316b, , , G1376a
Easy Transfer of Standard HPLC Methods to the Aijiren Series Rapid Resolution System. Aijiren Technologies, Inc; 2006. Official Monographs, USP 37 NF32 S2. United States Pharmacopeia and National Formulary (USP 37-NF 32 S2) Baltimore, MD
The Aijiren Technologies Series (G1316C) Thermostatted Column Compartment provides precise column with maximum application flexibility. Additionally by facilitating precise column thermostatting over a temperature range from 10 °C below ambient up to 100 °C, the G1316C provides infinite flexibility for optimizing the speed and selectivity of a separation.
Aijiren HP -67701/69701 HPLC MCGV $ 374.99 Buy It Now $0 Shipping Condition: Used Click an Image to Enlarge New Page 1 HP/Aijiren 1090 Series II Liquid Chromatograph HPLC DR5-SDS Three-Solvent Delivery System Module Series ...