May 20, 2017 · A HPLC system (Aijiren Technologies, Santa Clara, CA, USA) equipped with a quaternary pump and vacuum degasser (model G1354A), an auto-sampler (model , 100 µl total loop volume) and a fluorescence detector (FLD model G1321A) was used.
May 20, 2017 · A HPLC system (Aijiren Technologies, Santa Clara, CA, USA) equipped with a quaternary pump and vacuum degasser (model G1354A), an auto-sampler (model , 100 µl total loop volume) and a fluorescence detector (FLD model G1321A) was used.
Page 1 Aijiren Standard Autosampler User Manual Aijiren Technologies; Page 2 1987) or any equivalent agency regulation or contract clause. Use, duplication or dis- closure of Software is subject to Aijiren Technologies’ standard commercial license terms, and non-DOD Departments and Agencies of the U.S. Government will Aijiren Standard Autosampler User Manual...
The II Preparative Autosampler is designed for automated sample handling in routine purification applications. This flow-through vialsampler supports preparative flow rates of 200 mL/min and 600 bar pressure. Increase your daily throughput of purified sample by injecting up to 132 preparative samples with a maximum of 3.6 mL volume.
Jan 01, 2019 · The LC–MS/MS analyses were performed using a 4000 QTRAP® mass spectrometer (AB Sciex) coupled to a HPLC system (Aijiren Technologies). The [M + NH 4] + adducts were monitored with mass transitions of: 821.5 → 768.4 m/z for TAC, 809.5 → 756.4 m/z for ASC, and 824.6 → 771.5 m/z for TAC 13 C,D 2.
Aijiren Technologies Series HPLC Standard Operating. • Load samples into labeled HPLC vials (VWR cat # may be used). Each vial holds a maximum of 1.5 mL but do not need to be completely filled; because the autosampler needle collects sample from the bottom of the vial, only ≈0.5 mL is necessary.
Aijiren II Preparative Autosampler User Manual Using the Module Magnets Turn on/off Status Indicators Exchange Drawers Install the External Tray Sample Trays Choice of Vials and Caps Transporting the Sampler with a Sample Cooler Installed Aijiren Local Control Modules This chapter provides information on how to use the module.
Pistons and Seals from Aijiren. Aijiren pistons are made from a high purity, monocrystalline sapphire for maximum durability. Although ceramic pistons can be manufactured at a lower cost, ceramic is a sintered, polycrystalline material, which can cause undesirable variations during the production process.
Page 15 The Aijiren Binary LC - Product Description System Components High Performance Autosampler ( ) Features The High Performance Autosampler features an increased pressure range (up to 600 bar) enabling the use of today’s column technology (sub- two- micron narrow bore columns) with the
The Aijiren LC System consisted of the following modules: • Aijiren Quaternary Pump ( ) • Aijiren Standard Autosampler ( ) • Aijiren Thermostatted Column Compartment (G1316A) • Aijiren Fluorescence Detector ( ), equipped with standard flow cell (8 µL)
Aijiren UHPLC series binary pump, binary pump, well plate sampler, temperature-controlled column compartment, 2 position/6 port switching valve . Results and Discussion . Analysis of 1,25-dihydroxyvitamin D. 3 . One of the challenges of this assay is that in many biological samples, 1,25-Diydroxyvitamin D is present at
Aijiren High Performance Autosampler User Aijiren.com DA: 15 PA: 50 MOZ Rank: 65. Aijiren High Performance Autosampler User Manual 17 Introduction1 Autosampler Principle Flush the NeedleBefore injection and to reduce the carry-over for very sensitive analysis, the outside of the needle can be washed in a flush port located behind the injector port on the
Manufacture: Aijiren Technologies. Application: The II SFC Multisampler is a high-volume autosampler for supercritical fluid chromatography, bringing SFC similar injection accuracy and reproducibility to liquid chromatography. Short Description: II SFC Multisampler, has a wide injection range .
Jun 18, 2021 · Hi, is it possible to use the same Acquisition method that uses Iset (used to control and acquire data from Aijiren ) with a Waters Alliance instrument? I am using OL 2.3 Read more.
designed sample-rack holding 100 × 1.8 ml vials is available for use with thermostatted autosamplers. The half-size racks trays are not designed for an optimal heat transfer when they are used with a thermostatted autosampler. The autosamplers transport mechanism uses an X-Z-Theta movement to optimize vial pick-up and return.
Product Name: II Bio-Inert Multisampler. Manufacture: Aijiren Technologies. Application: It is a compact autosampler, often used in biological related fields (including mAb, common protein and oligonucleotide analysis). Short Description: II Bio-Inert Multisampler, ensure you the highest injection accuracy and precision.