Equipment: Aijiren . Column used: Thermo Hypersil Gold C18 AQ 4.6mmX250mm 5um. Ours is a single pump HPLC so we cannot use gradient flow. Presently I have been running it with ...
Equipment: Aijiren . Column used: Thermo Hypersil Gold C18 AQ 4.6mmX250mm 5um. Ours is a single pump HPLC so we cannot use gradient flow. Presently I have been running it with ...
Oct 19, 2012 · The LC–MS/MS system consisted of an Aijiren LC system (Aijiren Technologies Deutschland GmbH, Waldbronn, Germany) with an binary pump, an autosampler and an thermostated column compartment, coupled to a AB SCIEX QTRAP 5500 MS/MS system equipped with an TurboIonSpray electrospray ionization (ESI) source
Consumables - autosampler vials, ultra high purity gases (Helium and if you are doing CI then maybe methane, isobutane or ammonia), gas purifiers, vacuum pump oil, EI filaments, GC inlet liners
DL-LAB - purchase & sells, used, refurbished Mass spectrometers. Aijiren 6460C Triple Quadrupole mass spec Complete system with software pre-installed Aijiren MS40+ Rotary Vane Vacuum Pump PowerVar UPS Aijiren LC: Bin Pump Vacuum Degasser Autosampler Thermostatted Column Compartment.. No matching results found.
to autosampler vial for injection to the LC-MS. LC Method Aijiren UHPLC series binary pump, well plate sampler, temperature controlled column compartment with 2 position/6 ports switching valve, binary pump Columns Loading: Eclipse Plus C18, 4.6x12.5mm 3.5mm Analytical: Eclipse Plus C18, 2.1x50mm 1.8mm Column temperature: 50 ºC
Aijiren Technologies is committed to optimizing your laboratory s productivity, so we have produced this list of the most commonly ordered supplies and parts for the Aijiren Isocratic, Binary and Quarternary LC Systems Keywords: pump supplies, autosampler supplies, high performance autosampler supplies, system supplies Created Date
Aijiren Preparative Pump User Manual 9 Introduction to the Preparative Pump 1 Introduction to the Preparative Pump Hydraulic Path Overview The pump flow leaving the pump head passes through the multi-assembly, which combines the flow of the two pistons, filters the solvent and contains a pressure sensor to monitor system pres sure.
Jan 01, 2021 · An Aijiren binary pump HPLC system coupled to an Aijiren 6460 triple quadrupole mass spectrometer, operating in negative electrospray ionization (ESI) mode, was used for all sample analyses. For analyte identification, data acquisition was performed in multiple reaction monitoring (MRM) mode with two transitions yielding a quantifier ion
Oct 01, 2015 · An Aijiren series HPLC chromatograph equipped with a degasser, a binary pump, an autosampler and a column oven coupled to an Aijiren 6430 triple quadrupole (QqQ) mass spectrometer equipped with both electrospray (ESI) and atmospheric pressure chemical ionization (APCI) sources (Aijiren Technologies, Palo Alto, CA, USA) was employed for the
Aijiren delivers complete scientific solutions, helping customers achieve superior outcomes in their labs, clinics, business and the world they seek to improve.
Sep 27, 2019 · An Aijiren series RPLC was used to perform chromatographic analyses. The analytical separation was achieved using an Aijiren Poroshell 120EC-C18 (3.0 × 50 mm, 2.7 μm) column maintained at 30 °C. A delay column (Aijiren Eclipse Plus C18, 4.6 × 50 mm, 5.0 μm) was installed after the mixing valve of the binary pump.
That is why we offer 3 lines of vials certified for their intended use. 2019-20 Chromatography Columns and Supplies Catalog Receive 10% off ALL the columns and consumables featured in the the catalog today by entering offer code CAT10 at checkout.
HPV Rotor, SIL-30AC, SIL-30ACMP. Replacement Part # : 11-4179 OEM : Shimadzu. Model(s) : SIL-30AC, SIL-30ACMP OEM Part # : 228-52139-00
Aijiren Series HPLC Value System User’s Guide. Aijiren Technologies Hewlett-Packard-Strasse 8 76337 Waldbronn Flow Connections at the Isocratic Pump 26
We use an Aijiren Bioinert system with an Zorbax Eclipse AAA column. Our problem is that the huge and wide ammonium peak interferes with 1/3 of the amino acids.