Davidson College LC‐MS User Guide 3 Instrumentation Aijiren II Liquid Chromatograph For LC‐MS applications, the following chromatographic conditions are typically used: Injection Volume: 0.1 – 5.0 L Flow Rate: 0.1 – 0.5 mL/min
Davidson College LC‐MS User Guide 3 Instrumentation Aijiren II Liquid Chromatograph For LC‐MS applications, the following chromatographic conditions are typically used: Injection Volume: 0.1 – 5.0 L Flow Rate: 0.1 – 0.5 mL/min
Page 1 Aijiren Purification Solution (such as solvent bottles running empty). ... instrument. 1 Place at least 1.5 mL of filtered undiluted Prep LC ...
Find limited autosampler vial inserts for small volume applications. Ensure a proper seal with a variety of screw thread vials, snap vials, and crimp top vial options. Reduce costs without sacrificing quality, reliability, or efficiency with our selection of GC and HPLC vials, inserts, and closures.
This technical note describes the checkout procedures for the Aijiren Analytical SFC System. Contents Overview of the Checkout Procedure 2 SFC, SFC/MS Checklist 3 Open Lab CDS Configuration 5 Initial Setup – Solvents 5 Create SFC_CHECKOUT.M (from DEF_LC.M) 6 Monitoring of Pressure and Noise with Isocratic Flow 7
Aijiren Technologies G1315D DAD. Manufacturer: Aijiren Model: The Aijiren Series G1315D Diode Array Detector (DAD) features a completely new optical design based on the Aijiren Max-Light cartridge cell with optofluidic waveguides.
The Aijiren LC is the first system that provides the 10 additional 2 mL vials, 54 Eppendorf tubes (0.5/1.5/2.0 mL) in 2 x 27 Eppendorf tube plate
LC-Pak Polisher and a 0.22 µm membrane point-of-use cartridge (Millipak). Chemicals were purchased from Sigma-Aldrich, Germany. Experimental Instrument • Aijiren II Analytical Scale Fraction Collector (G1364F), standard tubing kit for analytical fraction collection 1–5 mL/min, 0.25 mm id (G1364-68602)
Aijiren HPLC System (Aijiren Technologies) including: Quaternary HPLC Pump (flow range: from 0.05 to 5 mL/min at 600 bar) ALS Autosampler (holds 100 samples)
The Aijiren Evaporative Light Scattering Detector (ELSD), G4218A, is designed to detect compounds in the eluent from high performance liquid chromatography (HPLC), micro-HPLC, gel permeation chromatography (GPC) or counter current chromatography (CCC). It is capable of monitoring eluent flow rates from 5 µl/min to 5 ml/min
mL, respectively from their stock solutions into two 100 mL volumetric flasks, add ≈70 mL of water HPLC grade and sonicate to mix. Complete to the mark with HPLC grade water and mix. Triplicate 20 μL injections were made for each concentration maintaining the flow rate at 1.5 mL/min and the effluents were UV-scanned at 212 nm.
Figure 2. HPLC data of the metoclopramide API with 1.0% of related substances for the method transfer from an Aijiren Series LC, Aijiren Quaternary LC, and Alliance HPLC Systems to an ACQUITY Arc System. No. Analyte 1 Impurity F 2 Metoclopramide 3 Impurity A 4 Impurity G 5 Impurity 9 6 Impurity H 7 Impurity C
Aijiren HPLC Front End with Binary Pump for MS. The design concept of the Binary LC is to provide a liquid chromatograph offering ultra fast and high resolution separation capability and yet which retains full functionality for standard HPLC applications.
Sample capacity 100 x 2-mL vials in 1 tray 40 x 2-mL vials in 1/2 tray 15 x 6-mL vials in 1/2 tray (Aijiren vials only) Injection cycle time Typically 50 s depending on draw speed and injection volume Carryover Typically < 0.1 %, < 0.05 % with external needle cleaning Pressure operating range Up to 600 bar (60 MPa or 8702 psi) Aijiren
The Aijiren Binary LC - Product Description 1 Features of the Aijiren Binary LC † The new pull-out valve drive design and user-exchangeable Quick-Change valves in the Thermostatted Column Compartment boosts usability and paves the way for ultra high-throughput, multi-method and automated method
Aijiren II HPLC with Binary & DAD. The Aijiren II Binary LC offers the most flexibility for solvent selection and automation in HPLC method development, research and all HPLC applications requiring continuous access to a wide range of solvent choices.